You have no items in your quote list.

*Images Are For Representation Purpose Only Actual Product May Differ

Silverline Biphasic Defibrillator With ECG And Printer - DF 301

Quick Overview

Product Overview:
  • Silverline Biphasic Defibrillator is used to perform defibrillation for the purpose of turning abnormal ECG rhythm into normal rhythm.
Specifications:
Model Number DF 301
Input 150~270 VAC , 50 Hz
Battery 12 V, 4.5 Ah
Operation By Front Panal Key Board, Encoder & ON-Off  By Front Panel Push Button
Display Size 7 inch
Input 150 ~ 276 VAC, 50 Hz
Output 17 V At 4 A
Power Consumption 30 Watts (Max) In ECG Mode
Operating Temperature -5°C To +50°C
Humidity Up To 95% Non Condensing
LED Indicator Low Battery And Battery Charging
DEFIB:
Operating Mode Manual
Energy 2 To 200 Joules In 12 Steps [2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200 Joules]
Charging Time Less Than 8sec
Synchronous Energy Delivery Begins Within
Paddle Assembly Energy Paddle Assembly With
Check Mode Manual Test Mode
AED Mode:
Waveform Bi Phasic
AEC Shock Series Energy Level From 150 To 200J
Shock Command Front Panel Button, Shock
Charging Time Less Than 7 seconds
Controls Analyze, Pause
Defibrillation Electrode Malfunction, Self Adhesive, Adult Electrodes
Voice And Text Prompts Voice And Text Prompts To Guide User
SpO2 (Optional):
Range 0-100%
Accuracy 70-100% ±2%, 50-69% ±3%
Pulse Rate Displayed When PR Is Deselected
Pulse Beep Step Less Volume Control
PR Range 10-250 bpm
Pacemaker (Optional):
Waveform Monophasic
Modes Demand Or Non Demand
Amplitude From 10 mA To 150 mA (Resolution Of 10 mA)
Pulse Width 40ms (±1ms)
Frequency From 20 ppm To 250 ppm (Increments Of 1 ppm)
Refectory Period 340 ms (From 30 To 80 ppm), 240 ms (From 90 To 180 ppm)
Maximum Output Voltage 150 V
Impedance Range 200 ? To 1 k?
PRINTER:
Paper Type Thermal Paper 50/55 mm Width, 20 Meters Length For 2 inch Printer
Event Printing Prints 5 Seconds Pre & Post ECG With Date, Time, Energy And Mode, Shock Status
ECG In Defib Mode Prints Last 10 sec ECG Through Paddle
Print Annotates In Defib Mode Time, Date, Mode, Lead Name ,Gain, Sweep Speed
ECG In Monitor Mode Prints Last 10 sec ECG Through Paddle
Print Annotates In Monitor Mode Time, Date, Selected Lead Name, Gain, Sweep Speed
Manual Defib Check Mode Print The Status Of Shock, Energy, Date And Time
NIBP (Optional):
Method Oscillometric
NIBP Interval User Selectable - 3 min To 120 min
Modes Manual, Auto
Cuff Deflation Automatic
Safety Features Automatic Deflation If Cuff Pressure Exceeds 280 mmHg
Range 10-250 mmHg
NIBP Status Ready - When Not Taking Reading Measuring - When Taking Reading Error - If Reading Could Not Be Taken Due To Some Error While Measuring
GMDN: 36791
Check Delivery Availability

View Price
  • Charging time less than 6 seconds
  • Adult and paediatric paddles support
  • Charge command automatic after identifying arrhythmia
  • Pitch variation with change in oxygen saturation
  • Rechargeable lithium battery with charger (11.1V)
  • 60 ms of the QRS peak
  • Coil retractable high voltage cable
  • Adults & paediatric paddle integrated to same handle
  • Rechargeable battery capacity 3 hours for monitor & 70~100 shocks on single charge