Ventox 5 Para Patient Monitor - (PM01)
Exclusive of 12% GST
₹27,798
Exclusive of 12% GST
Get Exclusive Deals on Patient Monitor
Request a callback
Share your thoughts on this product
Incorrect prices? Missing information? Delivery time too high?
Get Interest-free credit with easy and quick approval & hassle free payments
Know More
1 x Patient Monitor, 1 x Manual,
Description: Introducing the Ventox 5 Para Patient Monitor (PM01), a sophisticated medical consumable engineered to provide comprehensive patient monitoring in clinical settings. With its advanced features and high-resolution display, this monitor offers real-time analysis and accurate data management for healthcare professionals.
Key Features:
Benefits:
Sold by VENTOX HEALTHCARE & fulfilled byMedikabazaar
Country of Origin | India |
---|---|
ECG Specification | Lead Configuration |
5-Lead | 5-Lead: RA, LA, LL, RL, V. Lead Method: I, III, AVR, aVL, aVF, V |
HR Range | Adult: 15-300 bpm (beat/minute) |
Neonatal baby/children: 15-350 bpm (beat/minute) | 21% or ±1 bpm, the larger prevails |
Precision | Resolution: 1 bpm (beat/minute) |
Sensitivity: >200 uV (Peak-to-peak value) | Input Impedance |
>5 megohm | Bandwidth |
Diagnostic mode: 0.05-130 Hz | Monitoring Mode: 0.5-40 Hz |
Operation mode: 1-20 Hz | Common Mode Rejection Ratio |
Diagnostic mode: > 90 dB | Monitoring Mode: > 100 dB |
Operation mode: > 100 dB | NIBP Specification |
Measuring Method | Pulse wave oscillometry |
Work Mode | Manual/Automatic STAT |
Measuring Interval of Automatic Measuring Mode | 1.2.3.4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 min |
Measuring Time of STAT Mode | 5 minutes |
PR Range | 40-240 bpm |
Measuring Range and Precision | See table in the specification |
Overvoltage Protection | 300 mV |
Pacing Pulse Test | Amplitude |
2 mV-700 mV | Width |
0.1 ms-2 ms | Risetime |
10 µs-100 µs | Baseline Recovering Time |
After defibrillation | < 3 seconds |
Signal Range | 8 mV (Peak-to-peak value) |
Calibrating Signal | 1 mV (Peak-to-peak value) |
Precision: 5% | ST Segment Measuring Volume |
Measuring Range | -2.0 mV-+2.0 mV |
Measuring precision | Ranging -0.8 mV-0.8 mV, measuring error is ±0.02 mV or ±10%. The larger prevails. No definition for other ranges. |
RESP Specification | Measuring Method |
RA-LL impedance | RESP Impedance Measuring Range |
0.3-30 | Base Impedance Range |
Adult mode: 300 mmHg | Children mode: 240 mmHg |
Neonatal baby mode: 150 mmHg | SpO2 Specification |
SpO2 Range | 0-100% |
Precision | 70%-100%: 2 digits |
PR Range | 20-300 bpm |
TEMP Specification | Suitable for Temperature Sensor |
YSI series, CYF series | Channel Quantity |
Channels | Measuring Range |
-50°C-50°C | Resolution |
0.1°C | Precision |