Silverline Fetal Monitor - FM 301

Quick Overview

Product Overview:
  • Silverline Fetal Monitor is used to detect the fetal heartbeat for prenatal care.
Specifications:
Model Number FM 301
Power Supply:
AC Power 100V To 240V, 50/60 Hz
DC Power 9V, 5A
Battery Rechargeable Li-Ion Battery/7.4V 2200mAh
Charging Cycle More Than 500 Times
Battery Backup More Than 2 Hours
Alarm Levels High, Medium, Low
Ultrasound (FHR):
Measurement Method Wide Beam Pulse Doppler
Transducer Type 12-Crystal Ultrasound Transducer
FHR Measurement Range 30-240 bpm
Accuracy ±1 bpm
Intensity <3mW/cm2
Frequency 1 MHz ±3%
Resolution 1 bpm
TOCO:
Measurement Method Strain Gauge Sensor Element
Measurement Range 0~100%
Nonlinear Deviation ? ±8%
Baseline Setting 0, 5, 10, 15, 20 Can Be Selective
Resolution 0.01
Auto Offset Correction 3 Seconds After Connecting The Transducer
Auto Zero Adjust TOCO Value Is Set To Zero Negative Following A Negative Measure Value For 5 Seconds
NIBP (Optional):
Method Oscillometric
Operation Mode Manual, Automatic, Start
Measurement Unit mmHg/kPa Selectable
Measurement Interval In Auto Mode 1-480 Min
Resolution 1 mmHg
Accuracy:
Standard Deviation 8 mmHg
Mean Error ±5 mmHg
Measurement Range:
Systolic 40 To 270 mmHg
Diastolic 10 To 210 mmHg
Mean 20 To 255 mmHg
Printer:
Method Thermal Printer
Paper 112mm/Z-Fold, Thermo Sensitive Paper
Print Speed 1, 2, Or 3 cm/min
Record Way Real Time Recording And Review Printing
Maternal SpO2 / Pulse Rate (Optional):
Measurement Range 0-100%
Resolution 0.01
Accuracy ±2% (70%-100%), ±3% (Motion Or Low Perfusion), Unspecified Less Than 70%
PR Measurement Range 30~250 bpm
Accuracy ±2 Or ±2% Whichever Is Greater
Resolution 1 bpm
Fetal Movement Recording:
Technique Pulsed Doppler Ultrasound
GMDN: 60260
Check Delivery Availability

View Price
  • Display: foldable 10.4 inch colour LED
  • 12-Cystal pulse doppler transducer (waterproof probes are optional)
  • Large capacity storage space, 8640 hours for fetal trace storage
  • Medical and para-medical can input or, search by patient ID, name and mobile number
  • FHR signal quality indicator helps optimize the probe position
  • Event movement makes it easy to annotate perceived fetal movements (FM)
  • Fetal movement profile detects and automatically records gross fetal body movements
  • Heart rate offset mode allowing you to offset FHR 2 : -30bpm ~ +30bpm
  • Cross channel verification provides visual/audible indication when detects synchronous fetal or maternal heart rate or pulse rate signals, indicating that you may be monitoring duplicate signals
  • Fetal heart rate alarm provides both audible and visual alerts if heart rate is outside of the user defined high/low range
  • Improved fischer non-stress test (NST) report software allows interpretation of fetal heart rate and TOCO traces, and generates a report automatically
  • USB port: USB keyboard or mouse connection and software upgrading
  • Auditory, visual, delay of FHR alarm indication
  • Over pressure protection via software and hardware dual protection
  • Automatic fetal movement autograph
  • Manual fetal movement marker
  • Optional/upgradable :
  • Twins monitoring
  • Touch screen
  • Fetal stimulator
  • Maternal parameters (SpO2, NIBP, ECG, TEMP, RESP)
  • HDMI output
  • Central monitoring station
  • Waterproof FHR probe & TOCO probe
  • Keyboard & mouse control function
  • Advanced fischer NST report
  • USB port with patient data/NST report backup function

Reviews

Write Your Own Review

How do you rate this product? *

  1 * 2 * 3 * 4 * 5 *
Quality