You have no items in your quote list.

*Images Are For Representation Purpose Only Actual Product May Differ

Biphasic Defibrillator with AED Rescue Life 7

Quick Overview

Features:
* Close to the needs of the modern emergency medicine
* Rescue Life guarantees impact-proof larger TFT LCD color 7 display
* Powerful battery up to 5 hours continuous monitoring and different product configurations

Check Delivery Availability

View Price
Specifications:
<b>Technical Specifications : </b>
* Dimension: 369 x 240 x 340 mm
* Weight: 5.5 Kg with battery
* Electrical: AC 100-240 VAC, 50/60 Hz- inverter 12V car adapter (optional)
* Rechargeable: 15.0 V  3.2 Ah Lithium-ion battery
* Battery Operation Time : >5 hours
* Battery Charge Time: Max. 3 hours
* Capacity: 150 shocks at 230J with battery fully charged
* Software: Voice and texts multi language
* Memory: Internal flash 4 GB up to 300 hrs. of ECG data, events and usage review
* Review and printing database: Review and printing of archived events
<b> Environmental : </b>
* Temperature
* Operational -5° ~ 46° C
* Storage 20° ~ 50° C
* Relative humidity 10 ~ 95%
* Isolation: ECG type CF, Defibrillation type BF
* Water proof: Class IPX4
<b> DEFIBRILLATION : </b>
* Waveform
* Biphasic Truncated Exponential (BTE)
* HICAP technology (Large storage capacitor)
* Impedance: Compensated, range 25 - 200 Ohm
* Charge time: 8 sec for 230 J with battery fully charged
<b> AED MODE : </b>
* Energy: Fixed energy at 200 J
* Protocol: ERC 2015 CPR Guidelines with voice and text prompts
* Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
* Sensitivity
* Shockable rhythm-VF > 95%
* Shockable rhythm-VT > 75%
* Specificity: According to ERC 2010
* Normal sinusoidal rhythm > 99%
* Asystole and other non-shockable rhythms > 95%
* <b>Display : </b>
* Type: High contrast TFT color LCD 7 (800X480 dots)
* <b>ECG Monitoring : </b>
* Bandwidth: 0.5 - 120 Hz (-3 db) with filters off
* CMRR: > 95 db
* Input impedance: > 20 Mohm
* <b>Input: </b>
* Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard
* Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1& ..V6) - optional
* Gain: 2,5, 5, 10, 20, 40 mm/mV with patient cable. AUTO with pads
* Speed: 5, 10, 25, 50 mm/sec
* Filters: 550/60 Hz, EMG Filter, base line
* <b>Monitoring Mode: </b>
* Bandwidth: 0.6 - 40 Hz (-3 db)
* <b>Diagnostic Mode: </b>
* Bandwidth: 0.05 - 120 Hz (-3 db)
* HR range: 20 - 300 bpm (~ 2%), digital readout on the display
* Alarm: HR max settable 250 bpm; HR min 20 bpm
<b>SPO2:</b>
* SpO2 range : 0 - 100%
* HR range: 30 - 250 bpm
* Accuracy: 70 - 100% ~ 2% for adults with finger clip sensor
* Alarm: Adjustable min 50%
<b>NIBP:</b>
* Technique: Oscillometric
* NIBP Accuracy: Meets ANSI/AAMI SP10-2002, EN 1060-4
* Patient Application: Adult/Pediatric/Neonatal
* Systolic Range: Adult: 40-260mmHG
* Pediatric: 40-160 mmHG
* Neonatal: 40-130 mmHG
* Range MAP: Adult: 26-220 mmHG
* Pediatric: 26-133mmHG
* Neonatal: 26-110 mmHG
* Diastolic Range: Adult: 20-200 mmHG,
* Pediatric: 20-120mmHG
* Neonatal: 20-100 mmHG
* PR RANGE: 30-220 BPM
* PR Accuracy: +/-2% or +/3 bpm
* Operating Modes: Manual, Long Term Automatic, Stat, Service
* Auto Interval Periods: 1,2,3,4,5,10,15,30,60 and 90 minutes

Use spaces to separate tags. Use single quotes (') for phrases.

Reviews

Write Your Own Review

How do you rate this product? *

  1 * 2 * 3 * 4 * 5 *
Quality